The Weatherford Tool Interface Box (Standard and HD) is a portable, polypropylene-encased device designed for surface calibration and testing of HD wireline tools without requiring a full system setup, featuring automatic tool identification, fast data communication (150 kbps uplink, 16 kbps downlink), real-time tool control, and compatibility with Warrior software via USB and oscilloscope telemetry, operating within -40° to 210°F and powered by 120/240 VAC or 18-55 VDC inputs.

Tool Interface Box – Standard and HD

Calibrates and checks tools on surface only

Applications

  • Perform tool calibrations in lab or field locations
  • Surface tool checks before/after deploying tools in the well
  • Test tools in lab without complete system, TCU, and wireline (simulator)

Features and Benefits

  • Automatic tool polling identification and data loop generation
  • Fast inter-tool bus communications
  • Up-link data rate of 150 kb/seconds
  • Fast wireline down-link (16 Kbps) allows real-time control of toolstring
  • Send tool commands (e.g., opening/closing multi-arm caliper tool)

Tool Description

The Weatherford tool interface box is used to test HD tools using a workstation with Warrior on a workbench or at the surface before deploying tools in a well for memory operations. The TIB facilitates an easy method to qualify HD tools performance on surface without requiring a TCU, surface interface panel (HLP/HIP), wireline or a dummy line box (DLB).

Specifications

Hardware characteristics

  • Length: 13.37 in. (34.0 cm)
  • Width: 1.162 in. (29.5 cm)
  • Height: 6.00 in. (15.2 cm)
  • Weight: 8.0 lb (4.0 kg)
  • Temperature range: -40° to 210°F (-40° to 99°C)
  • Materials: Polypropylene
  • Display: Current / voltage LCD with back light, LED critical indicators
  • Connections: PC with Warrior /HD services: USB 2.0 (A/B); Oscilloscope telemetry: BNC

Electrical specifications

  • AC voltage (Input): 120/240 VAC with fuse (2.5/1.25 amp)
  • DC voltage (Input): 18 - 55 VDC battery input from MBS
  • Protection: Bus Fuse: 250 VDC, 0.5 Amp
  • Tool interface (Output): 15 – 55 VDC

Technical Specification Sheet