Telemetry Gamma Ray and CCL Tool
The Weatherford Telemetry Gamma Ray and CCL Tool is a corrosion-resistant, integrated logging instrument combining a sodium iodine scintillation gamma ray detector and casing collar locator with a telemetry control unit, enabling fast up-hole real-time data acquisition and communication at high temperatures (up to 350°F) and pressures (up to 15,000 psi), designed to correlate formation gamma radiation and wellbore tubulars with specifications including a 2.75-inch diameter, 47.69-inch length, 500 kbps tool bus rate, and gamma ray measurement range of 1-65,000 cps with 10% accuracy.
Telemetry Gamma Ray and CCL Tool
Provides integrated telemetry and correlation services.
Applications
- Facilitates the combination of HD compatible services into a single logging string.
Features and Benefits
- Fast up-hole telemetry
- Integrated gamma ray for correlation to formation
- Integrated casing collar locator (CCL) for correlation to wellbore tubulars
Tool Description
The Weatherford telemetry gamma ray and CCL is a combined gamma ray and CCL tool with a telemetry control unit. It provides a passive measurement of gamma radiation by means of a sodium iodine scintillation detector and identifies changes of metal thickness by means of a collar locator.
The telemetry control unit is the communications control center for the logging system. The tool controls the collection of data from the tools below and packages it for transmission to the surface system.
Specifications
Ratings and Dimensions
- Maximum temperature: 350°F (177°C)
- Maximum pressure: 15,000 psi (103.4 MPa)
- Outer diameter: 2.75 in. (70.0 mm)
- Length: 47.69 in. (1,211.0 mm)
- Weight: 44.6 lb (20.2 kg)
- Measure Points:
- Gamma Ray: 8.43 in. (214.0 mm)
- Casing Collar: 39.92 in. (1,014.0 mm)
- Materials: Corrosion resistant materials used throughout
Hardware Characteristics
- Combinability: All HD tools (RADii, iQ, PL, RAS, etc)
- Acquisition Mode: Real-time
TCU Electrical Specifications
- Voltage: 300 V DC
- Current: Load dependent
- Tool bus rate: 500 kbps
- Uplink rate: 150 kbps
- Downlink rate: 16 kbps
Gamma Ray Measurements
- Range: 1-65,000 cps
- Resolution: 1 cps
- Accuracy: 10%
- Sensitivity: (nominal) 1 count / API