Weatherford International

RADii Cement-Bond Tool – Small-to-Medium Diameter

The Weatherford RADii Cement-Bond Tool for small-to-medium diameters is a high-temperature, high-pressure logging instrument featuring a segmented receiver and single receiver to generate cement maps, traditional cement-bond logs, and variable-density logs for identifying cement channeling and assessing cement-bond quality and formation isolation, available in Probe telemetry, HD, and high-temperature versions, with specifications including a maximum temperature rating up to 475°F, pressure up to 20,000 psi, 1.69-inch diameter, and compatibility with casing/tubing from 2.38 to 7.50 inches OD.

RADii® Cement-Bond Tool – Small-to-Medium Diameter

Identifies cement channeling and generates traditional cement-bond and variable-density logs

Applications

  • Cement-bond quality
  • Formation isolation
  • Cement channeling

Features and Benefits

  • Probe® high-speed digital (HD) platform version compatible with fast telemetry
  • Full surface read out (SRO) and memory logging capabilities with HD version
  • Master calibration stored in tool memory for retrieval when no free pipe is encountered in the well
  • High-temperature version for hostile environments

Tool Description

The Weatherford small-to-medium diameter RADii segmented cement-bond tool uses a single ceramic transmitter, an eight-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map that enables identification of cement channeling while the single receiver generates the traditional cement-bond log (CBL) and a variable-density log (VDL).

The small-to-medium diameter RADii segmented cement bond tool comes in three configurations: Probe telemetry (PTX), HD, and high temperature.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C) (PTX), 475°F (246°C) (HD, High Temperature)
  • Maximum pressure: 20,000 psi (138 MPa) (PTX, High Temperature), 15,000 psi (103.4 MPa) (HD)
  • Outside diameter: 1.69 in. (43 mm)
  • Length: 8.60 ft (2.62 m)
  • Weight: 41 lb (18.60 kg) (PTX), 51 lb (23.2 kg) (HD)
  • Tensile strength: Tension and compression: 15,000 lb; Torque: 150 ft-lb
  • Measure points: Amplitude, transit time: 4.3 ft (1.3 m); VDL, signature: 3.3 ft (1.0 m)
  • Min/max casing/tubing OD: Min: 2.38 in. (60.45 mm); Max: 7.50 in. (190.50 mm)

Borehole Conditions

  • Borehole fluids: OBM and WBM
  • Tool positioning: Centralized with one each centralizer above and below
  • Logging speed: Recommended: 60 ft/min (18.2 m/min); Max: 100 ft/min (30.5 m/min) at 0.08 ft (.02 m) sample rate

Electrical

  • Current: 38 mA at 130 V (PTX, High Temperature); 50 mA at 50 V (SRO), 50 mA at 19.2 V (Memory) (HD)

Calibration

  • Primary: 5.5 in. (13.97 cm) pressurized calibration tank
  • Wellsite: Free pipe, stored calibration tank waveforms on demand

Hardware Characteristics

  • Source type: One piezoelectric crystal fired at 20 kHz, 50 ms intervals
  • Sensor type: Omni Receiver: One 20-kHz piezoelectric; Radial Receiver: One 8-segment 20-kHz piezoelectric
  • Fire rate: 20/s
  • Waveform: Analog: 3 ft (0.9 m), 5 ft (1.5 m); Digital: Telemetry Data
  • Record time: 1,300 us for each receiver; 250 us for each sector
  • Connections:
    • PTX, High Temperature: Top: 1 3/16 in. 12P type-A GO box; Bottom: 1 3/16 in. 12-pin type-A GO box
    • HD: Top: GOI box; Bottom: GOI pin
  • Combinability: GR, CCL, ProMac™, iQ™, temperature (PTX, High Temperature); GR, CCL, single or dual spaced neutron, temperature (HD)
  • Acquisition mode: SRO (PTX, High Temperature); SRO with telemetry control unit, Memory with MLT (HD)

Measurements (all configurations except where noted)

  • E1 Peak Amplitude
  • Sonic Waveform
  • Principle: Sonic wavetrain attenuation
  • Range: 200 to 1,500 us
  • Resolution: 3 ft/0.9 m; 5 ft/1.5 m
  • Precision (1 SD): < 1 mV (E1 Peak Amplitude)
  • Primary curves: Amplitude: 3ft (.9 m); Individual sector amplitudes: 3 ft (.9 m); TT: 3 ft (.9m); VDL 5 ft (1.5 m)
  • Secondary curves:
    • PTX and heavy duty: head voltage, internal temperature, accelerometer, volume
    • High temperature: head voltage, internal temperature

For more detailed technical information, refer to the technical specification sheet available on the Weatherford website.