Weatherford International

RADii Cement-Bond Tool – Medium Diameter

The Weatherford medium diameter RADii Cement-Bond Tool, compatible with the Fully Probe® HD platform and available in standard, temperature sub, and HD configurations, uses a single ceramic transmitter and segmented receivers to identify cement channeling and generate traditional cement bond and variable-density logs, operating at up to 350°F and 20,000 psi with a 2.75-inch diameter, suitable for casing/tubing from 4.5 to 11.6 inches, and designed for use in OBM and WBM borehole fluids with centralized positioning and logging speeds up to 100 ft/min.

Identifies cement channeling and generates traditional cement bond log and variable-density log

Applications

  • Cement-bond quality
  • Formation isolation
  • Cement channeling

Features and Benefits

  • Fully Probe® high-speed digital (HD) platform compatible
  • Full SRO and memory capability
  • Storable master calibration in tool memory for retrieval when no free pipe is encountered in the well
  • High-temperature (HT) version for hostile environments

Tool Description

The Weatherford medium diameter RADii segmented cement-bond tool uses a single ceramic transmitter, an eight-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map enabling cement-channeling identification while the single receiver generates the traditional cement-bond log (CBL) and a variable-density log (VDL).

The medium-diameter RADii segmented cement-bond tool comes in three configurations: standard, with temperature sub, and HD.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C)
  • Maximum pressure: 20,000 psi (138 MPa) (Standard/HD), 15,000 psi (103.4 MPa) (With Temperature Sub)
  • Outside diameter: 2.75 in. (69.85 mm)
  • Length: 8.73 ft (2.66 m) (Standard/HD), 9.39 ft (2.86 m) (With Temperature Sub)
  • Weight: 93 lb (42.18 kg)
  • Tensile strength: Tension: 50,000 lb; Compression: 15,000 lb
  • Casing/tubing OD: Min: 4.5 in. (115 mm); Max: 11.6 in. (295 mm)
  • Materials: Alloy steel (stainless also available); corrosion resistant materials used throughout; SST
  • Measure points: Amplitude, TT: 4.3 ft (1.3 m); VDL, signature: 3.3 ft (1.0 m); Borehole temp: 6.8 ft (1.98 m) (Temperature Sub only)

Borehole Conditions

  • Borehole fluids: OBM, WBM
  • Tool positioning: Centralized with one each centralizer above and below
  • Logging speed: Recommended: 60 ft/min (18.2 m/min); Max: 100 ft (30.5 m)/min at 0.08 ft (.02 m) sample rate

Electrical

  • Current: 45 mA at 130 V (Standard/With Temperature Sub); 65 mA at 50 V (SRO), 65 mA at 19.2 V (memory) (HD)

Calibration

  • Primary: 5.5 in. (13.97 cm) pressurized calibration tank
  • Wellsite: Free pipe, stored calibration tank waveforms on demand

Hardware Characteristics

  • Source type: One piezoelectric crystal fired at 20 kHz, 50 msec intervals
  • Sensor type: Omni receiver: One 20 kHz piezoelectric; Radial receiver: One 8-segment 20 kHz piezoelectric
  • Connections: Top: 1 3/16 in. 12-P GO box; Bottom: 1 3/16 in. 12-P GO box (Standard/With Temperature Sub); Top: GOI box, Bottom: GOI pin (HD)
  • Combinability: GR, CCL, ProMac™, iQ™, Temperature (Standard/HD); GR, CCL, single- or dual-spaced neutron (With Temperature Sub)
  • Acquisition mode: SRO (Standard/With Temperature Sub); SRO with TCU, Memory with MLT (HD)
  • Fire rate: 20/sec
  • Waveform: Analog: 3 ft (.9 m), 5 ft (1.5 m); Digital: telemetry data
  • Record time: 1,480 microseconds for each receiver; 500 microseconds for each sector

Measurements (all configuration except where noted)

  • E1 Peak Amplitude
  • Sonic Waveform
  • Principle: Sonic wavetrain attenuation
  • Range: 200 to 1,500 us
  • Resolution: 3 ft/0.9 m; 5 ft/1.5 m
  • Precision (1 SD): < 1 mV (E1 Peak Amplitude)
  • Primary curves: Amplitude: 3ft (.9 m); Individual sector amplitudes: (3 ft) (.9 m); TT: 3 ft (.9m); VDL 5 ft (1.5 m); Borehole temperature*: 6.48 (1.98 m)
  • Secondary curves: Probe telemetry and Temperature: Head Voltage, Internal Temperature; HD: Head voltage, internal temperature, accelerometer, volume

*Temperature sub configuration only

A technical specification sheet is available for download: RADii® Cement-Bond Tool - Medium Diameter (PDF)