Weatherford International

RADii Cement-Bond Tool - Large Diameter

The Weatherford RADii Cement-Bond Tool - Large Diameter is a high-temperature, high-pressure logging instrument featuring a single ceramic transmitter and segmented receivers that produce cement channeling maps, traditional cement bond logs, and variable-density logs for cement-bond quality and formation isolation in casing sizes from 4.5 to 20 inches, compatible with Fully Probe® HD platforms, available in Probe telemetry and HD configurations, and designed for use in oil-based and water-based muds with centralized positioning and corrosion-resistant materials.

RADii® Cement-Bond Tool - Large Diameter

Identifies cement channeling as well as generates the traditional cement bond log and a variable-density log.

Applications

  • Cement-bond quality
  • Formation isolation
  • Cement channeling

Features and Benefits

  • Fully Probe® high-speed digital (HD) platform compatible
  • Full SRO and memory capability
  • Master calibration storage in tool memory retrievable when no free pipe is encountered in the well
  • High temperature (HT) version for hostile environments

Tool Description

The Weatherford large diameter RADii segmented cement-bond tool uses a single ceramic transmitter, a sixteen-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map enabling identification of cement channeling while the single receiver generates the traditional cement-bond log (CBL) and a variable-density log (VDL).

The large diameter RADii segmented cement bond tool comes in two configurations: Probe telemetry (PTX) and HD.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C)
  • Maximum pressure:
    • PTX: 20,000 psi (138 MPa)
    • HD: 15,000 psi (103.4 MPa)
  • Outside diameter: 3.5 in. (88.9 mm)
  • Length: 9.35 ft (2.82 m)
  • Weight: 175.7 lb (9.40 kg)
  • Tensile strength: Tension: 40,000 lb; Compression: 40,000 lb
  • Casing/tubing OD (in./mm): Min: 4.5 in. (115 mm); Max: 20 in. (508 mm)
  • Measure points (ft/m): Amplitude, TT: 4.3 ft (1.3 m); VDL, signature: 3.3 ft (1.0 m)
  • Materials: Corrosion resistant materials used throughout (HD: N/A)

Borehole Conditions

  • Borehole fluids: OBM, WBM
  • Tool positioning: Centralized with one each centralizer above and below
  • Logging speed: Recommended: 60 ft/min (18.2 m/min); Max: 100 ft (30.5 m)/min at 0.08 ft (.02 m) sample rate

Electrical

  • Current:
    • PTX: 82 mA at 130 V
    • HD: 90 mA at 50 V (SRO); 90 mA at 19.2 V (memory)

Calibration

  • Primary: 9.625 in. (24.4 cm) pressurized calibration tank
  • Wellsite: Free pipe, stored calibration tank waveforms on demand

Hardware Characteristics

  • Source type: One piezoelectric crystal fired at 20 kHz, 50 ms intervals
  • Sensor type:
    • Omni receiver: One 20-kHz piezoelectric
    • Radial receiver: One 8-segment 20-kHz piezoelectric
  • Fire rate: 20/sec
  • Waveform: Analog: 3 ft (.9 m), 5 ft (1.5 m); Digital: telemetry data
  • Record time: 1,400 microns for each receiver; 500 microns for each sector
  • Combinability: GR, CCL, ProMac™, iQ™, temperature
  • Connections: Top: GOI box; Bottom: GOI pin
  • Acquisition mode: SRO; SRO with TCU; Memory with MLT

Measurements (all configuration except where noted)

  • E1 Peak Amplitude
  • Sonic Waveform
  • Principle: Sonic wavetrain attenuation
  • Range: 200 to 1,500 µs
  • Resolution: 3 ft/0.9 m; 5 ft/1.5 m
  • Precision (1 SD): < 1 mV (N/A for some configurations)
  • Primary curves:
    • Amplitude: 3ft (.9 m)
    • Individual sector amplitudes: (3 ft) (.9 m)
    • TT: 3 ft (.9m)
    • VDL 5 ft (1.5 m)
    • Borehole temperature*: 6.48 (1.98 m)
  • Secondary curves:
    • Probe telemetry and Temperature: Head Voltage, Internal Temperature
    • HD: Head voltage, internal temperature, accelerometer, volume

*Temperature sub configuration only


For more detailed technical information, refer to the RADii® Cement-Bond Tool - Large Diameter Technical Specification Sheet (PDF).