RADii Cement-Bond Tool - Large Diameter
The Weatherford RADii Cement-Bond Tool - Large Diameter is a high-temperature, high-pressure logging instrument featuring a single ceramic transmitter and segmented receivers that produce cement channeling maps, traditional cement bond logs, and variable-density logs for cement-bond quality and formation isolation in casing sizes from 4.5 to 20 inches, compatible with Fully Probe® HD platforms, available in Probe telemetry and HD configurations, and designed for use in oil-based and water-based muds with centralized positioning and corrosion-resistant materials.
RADii® Cement-Bond Tool - Large Diameter
Identifies cement channeling as well as generates the traditional cement bond log and a variable-density log.
Applications
- Cement-bond quality
- Formation isolation
- Cement channeling
Features and Benefits
- Fully Probe® high-speed digital (HD) platform compatible
- Full SRO and memory capability
- Master calibration storage in tool memory retrievable when no free pipe is encountered in the well
- High temperature (HT) version for hostile environments
Tool Description
The Weatherford large diameter RADii segmented cement-bond tool uses a single ceramic transmitter, a sixteen-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map enabling identification of cement channeling while the single receiver generates the traditional cement-bond log (CBL) and a variable-density log (VDL).
The large diameter RADii segmented cement bond tool comes in two configurations: Probe telemetry (PTX) and HD.
Specifications
Ratings and Dimensions
- Maximum temperature: 350°F (177°C)
- Maximum pressure:
- PTX: 20,000 psi (138 MPa)
- HD: 15,000 psi (103.4 MPa)
- Outside diameter: 3.5 in. (88.9 mm)
- Length: 9.35 ft (2.82 m)
- Weight: 175.7 lb (9.40 kg)
- Tensile strength: Tension: 40,000 lb; Compression: 40,000 lb
- Casing/tubing OD (in./mm): Min: 4.5 in. (115 mm); Max: 20 in. (508 mm)
- Measure points (ft/m): Amplitude, TT: 4.3 ft (1.3 m); VDL, signature: 3.3 ft (1.0 m)
- Materials: Corrosion resistant materials used throughout (HD: N/A)
Borehole Conditions
- Borehole fluids: OBM, WBM
- Tool positioning: Centralized with one each centralizer above and below
- Logging speed: Recommended: 60 ft/min (18.2 m/min); Max: 100 ft (30.5 m)/min at 0.08 ft (.02 m) sample rate
Electrical
- Current:
- PTX: 82 mA at 130 V
- HD: 90 mA at 50 V (SRO); 90 mA at 19.2 V (memory)
Calibration
- Primary: 9.625 in. (24.4 cm) pressurized calibration tank
- Wellsite: Free pipe, stored calibration tank waveforms on demand
Hardware Characteristics
- Source type: One piezoelectric crystal fired at 20 kHz, 50 ms intervals
- Sensor type:
- Omni receiver: One 20-kHz piezoelectric
- Radial receiver: One 8-segment 20-kHz piezoelectric
- Fire rate: 20/sec
- Waveform: Analog: 3 ft (.9 m), 5 ft (1.5 m); Digital: telemetry data
- Record time: 1,400 microns for each receiver; 500 microns for each sector
- Combinability: GR, CCL, ProMac™, iQ™, temperature
- Connections: Top: GOI box; Bottom: GOI pin
- Acquisition mode: SRO; SRO with TCU; Memory with MLT
Measurements (all configuration except where noted)
- E1 Peak Amplitude
- Sonic Waveform
- Principle: Sonic wavetrain attenuation
- Range: 200 to 1,500 µs
- Resolution: 3 ft/0.9 m; 5 ft/1.5 m
- Precision (1 SD): < 1 mV (N/A for some configurations)
- Primary curves:
- Amplitude: 3ft (.9 m)
- Individual sector amplitudes: (3 ft) (.9 m)
- TT: 3 ft (.9m)
- VDL 5 ft (1.5 m)
- Borehole temperature*: 6.48 (1.98 m)
- Secondary curves:
- Probe telemetry and Temperature: Head Voltage, Internal Temperature
- HD: Head voltage, internal temperature, accelerometer, volume
*Temperature sub configuration only
For more detailed technical information, refer to the RADii® Cement-Bond Tool - Large Diameter Technical Specification Sheet (PDF).