RADii Cement-Bond Tool - High Temperature
The Weatherford RADii Cement-Bond Tool - High Temperature is a high-temperature (up to 475°F) and high-pressure (20,000 psi) rated logging tool available in 2.75 and 3.5-inch sizes, featuring a single ceramic transmitter and segmented receivers that generate cement maps to identify cement channeling, traditional cement-bond logs, and variable-density logs for evaluating cement-bond quality and formation isolation in hostile well environments.
RADii® Cement-Bond Tool - High Temperature
Identifies cement channeling and generates the traditional cement-bond log and a variable-density log.
Applications
- Cement-bond quality
- Formation isolation
- Cement channeling
Features and Benefits
- Master calibration storage in tool memory, retrievable when no free pipe is encountered in the well
- High-temperature (HT) rated for hostile environments
Tool Description
The Weatherford large-diameter RADii segmented cement-bond tool uses a single ceramic transmitter, a sixteen-segment receiver at 3 ft, and a single receiver at 5-ft spacing. The segmented receiver generates a cement map enabling cement-channeling identification while the single receiver generates a traditional cement-bond log (CBL) and a variable-density log (VDL).
The high-temperature RADii segmented cement-bond tool comes in 2-3/4 in. and 3-1/2 in. sizes.
Specifications
Ratings and Dimensions
- Maximum temperature: 475°F (246°C)
- Maximum pressure: 20,000 psi (138 MPa)
- Outside diameter:
- 2.75 in. (69.85 mm)
- 3.5 in. (88.9 mm)
- Length: 11.35 ft (3.46 m) for both sizes
- Weight:
- 130 lb (59.1 kg) for 2-3/4 in.
- 185 lb (83.92 kg) for 3-1/2 in.
- Tensile strength:
- 2-3/4 in.: Tension 15,000 lb, Compression 35,000 lb
- 3-1/2 in.: Tension 40,000 lb, Compression 40,000 lb
- Casing/tubing OD:
- 2-3/4 in.: Min 4.5 in. (115 mm), Max 10.75 in. (270 mm)
- 3-1/2 in.: Min 4.5 in. (115 mm), Max 20 in. (508 mm)
- Measure points: Amplitude, TT: 4.3 ft (1.3 m); VDL, signature: 3.3 ft (1.0 m)
Borehole Conditions
- Borehole fluids: OBM, WBM
- Tool positioning: Centralized with one each centralizer above and below
- Logging speed:
- Recommended: 60 ft/min (18.2 m/min)
- Max: 100 ft (30.5 m)/min at 0.08 ft (0.02 m) sample rate
Electrical
- Current:
- 2-3/4 in.: 38 mA at 130 V
- 3-1/2 in.: 82 mA at 130 V
Calibration
- Primary:
- 2-3/4 in.: 5.5 in. (13.97 cm) pressurized calibration tank
- 3-1/2 in.: 9.625 in. (24.4 cm) pressurized calibration tank
- Wellsite: Free pipe, stored calibration tank waveforms on demand