Quantum Geothermal PT Gauge
The Quantum™ Geothermal PT Gauge by Weatherford is a high-temperature subsurface memory tool designed for geothermal and gradient surveys, capable of accurately measuring and recording downhole pressure up to 8,500 psi and temperature up to 662°F (350°C) with fast response RTD sensors, featuring a durable Inconel 825/Hastelloy construction, USB communication, AA battery power, and operational flexibility in both memory and surface readout modes.
Quantum™ Geothermal PT Gauge
Enables precision pressure temperature surveys in ultra-high temperature environments
Applications
- Geothermal
- Gradient surveys
Features and Benefits
- Operating temperatures up to 662°F (350°C) make it suitable for geothermal and high temperature wells
- Capable of operating in both memory and surface readout mode, offering operational flexibility
Tool Description
The Weatherford geothermal PT gauge is a subsurface high-temperature memory tool designed to continuously measure and record downhole pressure and temperature.
The PT gauge has excellent thermal protection from temperatures up to 662°F (350°C). A fast response temperature sensor (RTD) provides a high accuracy temperature profile of the well.
Communication is via USB interface and the tool is powered using AA cell batteries.
Specifications
Ratings and Dimensions
- Outer diameter: 1.75 in. (44.45 mm)
- Length: 59.0 in. (1.49 m)
- Weight: 28.0 lb (12.7 kg)
- Maximum temperature: 4 hours at 662°F (350°C)
- Pressure range: 8,500 psi (58.6 MPa)
Hardware Characteristics
- Transducer type:
- Pressure: Piezo resistive
- Temperature: RTD
- Battery type: AA Lithium / Alkaline Carrier
- Materials: Inconel 825/Hastelloy (NACE MRO 175)
- Connections:
- Top: 5/8 in. API Pin (Memory Configuration)
- Top: 1 3/16 in.-12 GO Box (SRO Configuration)
- Bottom: 5/8 in. API Box
Pressure Measurements
- Pressure range: 0 to 5,000 psi / 0 to 8,500 psi (0 to 34.4 MPa / 0 to 58.6 MPa)
- Sampling rate: 1 sps
- Resolution: 0.0003% F.S.
- Accuracy: 0.024% F.S. or 0.05% F.S.
Temperature Measurements
- Maximum temperature: 4 hours at 662°F (350°C)
- Resolution: 0.0018°F (0.001°C)
- Accuracy: ± 0.449°F (± 0.25°C)
- Response time: 1.5 sec / 10°C
Electrical Specifications
- Consumption: 3.6V
- Maximum data: 8,000,000 sets
- Interface: USB URod
Application
- Acquisition Mode: Memory / SRO
- Logging time: 4 hr at 662°F (350°C), 6 hr at 572°F (300°C)