Long-Dome, 1-in. Conventional Gas Lift Valve | Weatherford International
The Weatherford Long-Dome, 1-in. Conventional Gas Lift Valve enhances gas lift performance by doubling the N2 dome volume to reduce load rates by 38%, increase gas injection rates by up to 32%, allow additional stem travel with less overburden pressure, minimize multi-pointing issues, and improve production efficiency without reducing tubing size, effectively stabilizing gas injections and reducing valve sensitivity to pressure fluctuations compared to standard 1-in. valves.
Long-Dome, 1-in. Conventional Gas Lift Valve
Provides additional stem travel with less overburden pressure
Applications
- Continuous gas-lift injection
- Production-performance enhancement
Features and Benefits
- Increases N2 dome volume 100%
- Allows gas-lift injection rate to be increased by up to 32%
- Lowers load rate by 38%
- Allows additional stem travel with less overburden pressure to open gas lift valve
- Reduces multi-pointing prevalent in 1-in. gas lift valves due to high load rate
- Larger dome volume allows for more controlled and prolonged single-point injections that can help reduce slugging
- Low-cost method of enhancing flow performance of gas lift valve
- Compressor efficiency decreases CO2 emissions
Tool Description
The Weatherford Long-Dome, Gas Lift Valve is an advanced version of the standard conventional 1-in. valve, designed to improve performance in gas lift applications. By extending the dome volume of the 1-in. valve, load rates are proven to be significantly reduced, thereby improving pressure management, which helps stabilize gas injections and reduces valve sensitivity to pressure fluctuations. The long-dome, one-inch conventional valve helps eliminate multi-pointing issues and improves production efficiency by allowing lower pressure differentials deeper in the well—all without having to reduce tubing size.
Compared to the 1.5-in. conventional valve, a proven better performing valve, the load rate of the 1-in. valve is much higher. Higher load rates increase risks with multi-pointing and cause limitations with the valve fully opening. The goal of the long-dome, 1-in. conventional valve is to reduce load rates while performing similarly to the 1.5-in. valve and with the option to maintain larger tubing size while fitting inside smaller casing sizes.
C-1 and C-1LD Load Rate and Stem-Travel Testing*
| Valve Model | 800 psi TRO Load Rate | 800 psi TRO Stem Travel | 1,200 psi TRO Load Rate | 1,200 psi TRO Stem Travel | 2,000 psi TRO Load Rate | 2,000 psi TRO Stem Travel |
|---|---|---|---|---|---|---|
| C-1 | 1,453 | 0.125 | 1,503 | 0.129 | 2,149 | 0.137 |
| C-1LD | 894 | 0.137 | 1,005 | 0.143 | 1,850 | 0.150 |
| Reduction | 38% | 33% | 14% |
*Testing data compares standard C-1 gas lift valve and C1-LD 1-in. Conventional Long-Dome gas lift valve.
Standard C-1 gas lift valve (left) and C1-LD 1-in. Conventional Long-Dome gas lift valve (right).