IntelleX Memory Correlation Tool
The Weatherford IntelleX Memory Correlation Tool is a slickline-conveyed device combining gamma ray, casing collar locator, piezoresistive pressure, and temperature sensors with 8MB flash memory to store up to 550,000 data sets, designed for high-resolution depth determination, bottomhole pressure/gradient surveys, sliding sleeve position monitoring, and fluid movement detection in wells, featuring a 1.69-inch diameter, 5.55-foot length, operating up to 347°F and 15,000 psi, with precise temperature accuracy (<±0.9°F), gamma ray counting up to 3,000 cps, and powered by a 19.5 V lithium battery.
IntelleX™ Memory Correlation Tool
Provides slickline correlation for multiple applications
Applications
- Slickline-conveyed service for the following applications:
- High-resolution depth determination
- Bottomhole pressure (BHP)/gradient services
- Sliding sleeve position determination
- Detect fluid movement in production/injection wells
Features and Benefits
- Integrated gamma ray/casing collar locator (CCL)
- Piezoresistive pressure and temperature
- 8MB memory to store 550,000 data sets
Tool Description
The Weatherford IntelleX memory correlation tool (MCT) is a combined CCL, gamma ray, piezoresistive pressure, and temperature tool ideal for high-resolution depth determination, BHP/gradient surveys, monitoring sliding sleeve (SSD) positioning, and determining fluid movement in producing or injecting wells.
The tool can be programmed to sample any or all channels at up to 32 samples per second. The 8 MB non-volatile flash memory can store up to 550,000 data sets.
Specifications
Ratings and Dimensions
- Outer diameter: 1.69 in (43.0 mm)
- Length: 5.55 ft (1,691.0 mm)
- Weight: 29.8 lb (13.5 kg)
- Maximum temperature: 347°F (175°C)
- Maximum pressure: 15,000 psi (103.4 mPa)
Hardware Characteristics
- Transducer type: Piezoresistive
- Housing: Corrosion resistant | 17-4PH (standard) or NACE MR-01-75
- Acquisition mode: Memory
- Connection: Top/bottom: 15/16 in. x 10UN (5/8 in. sucker rod)
Temperature Measurements
- Range: 32 – 345.0 °F (0 – 175.0 °C)
- Accuracy: < ±0.9°F (< ±0.5°C)
- Resolution: < 0.02°F @ 1 sps (< 0.01°C @ 1 sps)
Gamma Ray Measurements
- Maximum counting rate: 3,000 cps, 4,000 API
- API calibration: 1 CPS/API unit
Casing Collar Locator
- Range: 2 3/8 to 7 in. (60.5 to 177.8 mm)
- Principle: Magnetic flux line
Electrical Specifications
- Battery: 5 x ‘C’ cell lithium battery
- Voltage (DC): 19.5 V, 6.2 Ahr
- Memory rate: 179 hr @ 1 sps | 52 hs @ 1 sps PTGR
- Memory capacity: 8MB
- Current: 5 mA standby | 54mA sampling
- Consumption: At 1 sps > 4.3 days operation from a single battery