IntelleX HPHT Quartz Gauge Tool | Weatherford International
The Weatherford IntelleX HPHT Quartz Gauge Tool is a slickline, e-line, or coiled tubing conveyed pressure and temperature memory gauge designed for extended well surveys, offering up to 1.4 million data sets stored in 8 MB memory, capable of operating at temperatures up to 392°F and pressures up to 30,000 psi, with high accuracy (0.02% FS) and long operating life, suitable for bottomhole pressure surveys, sliding sleeve monitoring, and fluid movement determination in wells.
IntelleX™ HPHT Quartz Gauge Tool
Provides precise pressure and temperature measurement on extended well surveys.
Applications
- Bottomhole pressure (BHP)/gradient surveys
- Monitoring sliding sleeve (SSD) positioning
- Determining fluid movement in producing or injecting wells
Features and Benefits
- Memory capacity of 8 MB and can store up to 1.4 million data sets for extended pressure surveys
- Programmable with any combination of sample rates and trigger events
Tool Description
The Weatherford IntelleX HPHT quartz memory gauge is a slickline, e-line, or coiled tubing conveyed PT gauge, available in various ODs and pressure ratings for a range of applications.
Memory capacity is 8 MB and up to 1.4 million data sets for more than 400 days of continuous recording at 2 samples/min.
Specifications
Ratings and Dimensions
- Outer diameter: 1.25 in. (32.0 mm) or 1.375 in. (34.9 mm)
- Length: 2.44 ft (0.74 m)
- Weight: 15 lb (6.8 kg) or 15.6 lb (7.07 kg)
- Maximum temperature: 392°F (200°C)
- Maximum pressure: 20,000 psi (137.9 MPa), 25,000 psi (172.4 MPa), or 30,000 psi (206 MPa)
- Measure point: 2.7 in. (68.58 mm) from bottom of tool
- Materials: Inconel 25k psi and MP35N 30k psi rated (NACE MR-10-75 Compatible)
- Connection: Top/Bottom 15/16 in. x 10UN (5/8-in. Sucker Rod)
Measurements
- Memory Capacity: 8 MB for up to 1.4 million data sets
-
2 days (P/T @ 8 samples/sec)
-
13 days (P/T @ 1 sample/sec)
-
400 days (P/T @ 2 samples/min)
-
- Acquisition mode: Memory
- Maximum operating life:
- 200 hr at 392°F (200°C)
- 1,000 hr at 347°F (175°C)
- 2,000 hr at 329°F (165°C)
- 4,000 hr at 302°F (150°C)
- Primary output: 0.01 Pressure
- Secondary output: 0.02 Temperature
Pressure Measurements
- Range: 15,000 psi (103.4 MPa)
- Accuracy: 0.02% FS
- Resolution: < 0.1 psi
- Drift: 0.02% FS per year
Electrical Specifications
- Voltage: 3 – 9 Vdc
- 5 Vdc power supplied via USB (programming and data upload)
- 7.3 Vdc power supplied via 2 x “C” cell battery pack
- Current Consumption: < 2 mA (standby), < 6 mA (sampling)
- Power Requirements: 2 X ‘C’ Lithium Battery 7.34V (> 10 days operation at 1 sample/sec) 6.5Ah