Gamma Ray Tool | Weatherford International
The Weatherford Gamma Ray Tool is a compact, robust, and accurate downhole instrument designed for calibrated cased-hole formation evaluation and correlation, capable of measuring natural gamma-ray flux with high resolution and sensitivity under harsh conditions (up to 350°F and 15,000 psi), featuring a thallium-activated sodium iodide sensor, combinability with cement bond and casing collar locator logs, and specifications including a 1.69-inch diameter, 28.3-inch length, and tensile strength up to 65,000 lb tension, enabling shaly formation evaluation and wellbore tubular correlation with data rates up to 20 frames/sec and calibrated against Houston API pits and thorium blankets.
Gamma Ray Tool
Enables calibrated cased-hole formation evaluation and correlation
Applications
- Correlation to formation and wellbore tubulars
- Shaly formation evaluation
Features and Benefits
- Combinable with:
- Cement bond logs to fully understand zonal isolation
- CCL to provide baseline completion correlation
Tool Description
The Weatherford gamma ray tool is compact, robust, and accurate. It precisely measures natural gamma-ray flux in a wellbore.
Specifications
Ratings and Dimensions
- Maximum temperature: 350°F (177°C)
- Maximum pressure: 15,000 psi (103.4 MPa)
- Outside diameter: 1.69 in. (43.3 mm)
- Length: 28.3 in. (719 mm)
- Weight: 12.7 lb (5.8 kg)
- Min casing/tubing OD: 2.38 in. (60.5 mm)
- Max casing/tubing OD: 7.0 in. (178 mm)
- Tensile strength:
- Tension: 65,000 lb
- Compression: 130,000 lb
- Torque: 150 ft-lb
- Measure point: 6.4 in. (163 mm)
Borehole Conditions
- Logging speed:
- Recommended: 60 ft/min (18.2 m/min)
- Maximum: 100 ft/min (30.5 m/min) at 0.08 ft (.02 m) sample rate
- Tool positioning: Centralized or eccentralized
Hardware Characteristics
- Sensor type: Thallium-activated sodium iodide crystal
- Transmission type: Analog, pulse, or telemetry
- Data rate: 20 frames/sec at 20 kHz
- Combinability: Radial bond tool, cement-bond log, temperature
- Connections: GO top / GO pin bottom
Electrical
- Voltage: 100 V DC
Measurements
- Principle: Natural gamma radiation
- Range: 0 to 10,000 counts per second
- Resolution: 6.0 in. (152.5 mm)
- Accuracy (1SD): ± 5%
- Sensitivity: Approximately 0.998 counts/s per API unit
- Primary curves: GR (API)
- Secondary curves: Head voltage, internal temperature (telemetry only)
Calibration
- Primary: Houston API pits
- Wellsite verifier: Thorium blanket