Weatherford International

Gamma Gun – Scintillation Tool

The Weatherford Gamma Gun – Scintillation Tool is a rugged, compact gamma ray and casing collar locator (CCL) device with a highly sensitive scintillation detector designed for accurate correlation of ballistic services in cased-hole and perforating formation applications, available in multiple single-fire sizes (1-11/16 in., 2-3/4 in., and 3-1/8 in.) with specifications including up to 350°F temperature tolerance, 20,000 psi pressure rating, and tensile strengths up to 60,000 lb, enabling reliable operation in extreme environments.

Gamma Gun – Scintillation Tool

Provides accurate correlation of ballistic services

Applications

  • Cased-hole
  • Perforating formation correlation

Features and Benefits

  • Highly sensitive scintillation detector
  • Compact gamma ray and casing collar locator (CCL)

Tool Description

The Weatherford gamma gun-scintillation tool is a ruggedized tool fitted with a scintillation detector on the lower section of the tool and a passive CCL at the top.

The tool is designed to be run with a shooting adapter at the bottom to suit the customer’s choice of gun system. The rugged design and sensitive detector enable the tool to operate reliably in the most extreme environments.

Specifications

Ratings and dimensions (single fire)

  • 1-11/16 in. Single Fire

    • Maximum temperature: 350°F (177°C) for 4 hours
    • Maximum pressure: 20,000 psi (138 MPa)
    • Outer diameter: 1.69 in. (42.93 mm)
    • Length: 53.5 in. (1531.62 mm)
    • Weight: 21.0 lb (9.5 kg)
    • Minimum casing/tubing OD: 2.375 in. (60.325 mm)
    • Maximum casing/tubing OD: 7.0 in. (178.0 mm)
    • Measurement points: Gamma Ray: 9.0 in. (228.6 mm); Casing Collar Locator: 47.0 in. (1193.8 mm)
    • Tensile strength: Tension: 60,000 lb; Compression: 25,000 lb; Torque: 150 lb ft (203 N-m)
    • External markings: —
  • 2-3/4 in. Single Fire

    • Maximum temperature: 350°F (177°C) for 4 hours
    • Maximum pressure: 20,000 psi (138 MPa)
    • Outer diameter: 2.75 in. (69.85 mm)
    • Length: 57.3 in. (1455.42 mm)
    • Weight: 50.0 lb (23.0 kg)
    • Minimum casing/tubing OD: 3.5 in. (88.9 mm)
    • Maximum casing/tubing OD: 7.0 in. (178.0 mm)
    • Measurement points: Gamma Ray: 11.8 in. (299.72 mm); Casing Collar Locator: 47.0 in. (1193.8 mm)
    • Tensile strength: Tension: 60,000 lb; Compression: 25,000 lb; Torque: 150 lb ft (203 N-m)
    • External markings: —
  • 3-1/8 in. Single Fire

    • Maximum temperature: 350°F (177°C) for 4 hours
    • Maximum pressure: 18,000 psi (124 MPa)
    • Outer diameter: 3.125 in. (79.375 mm)
    • Length: 57.12 in. (1450.85 mm)
    • Weight: 67.0 lb (30.0 kg)
    • Minimum casing/tubing OD: 3.5 in. (88.9 mm)
    • Maximum casing/tubing OD: 11.75 in. (298.45 mm)
    • Measurement points: Gamma Ray: 13.5 in. (342.9 mm); Casing Collar Locator: 47.65 in. (1210.31 mm)
    • Tensile strength: Tension: 60,000 lb; Compression: 25,000 lb; Torque: 150 lb ft (203 N-m)
    • External markings: —
  • 2-3/4 in. Single Fire Positive

    • Maximum temperature: 350°F (177°C) for 4 hours
    • Maximum pressure: 20,000 psi (138 MPa)
    • Outer diameter: 2.75 in. (69.85 mm)
    • Length: 57.3 in. (1455.42 mm)
    • Weight: 50.0 lb (23.0 kg)
    • Minimum casing/tubing OD: 4.5 in. (114.3 mm)
    • Maximum casing/tubing OD: 7.0 in. (178.0 mm)
    • Measurement points: Gamma Ray: 11.8 in. (299.72 mm); Casing Collar Locator: 47.0 in. (1193.8 mm)
    • Tensile strength: Tension: 60,000 lb; Compression: 25,000 lb; Torque: 150 lb ft (203 N-m)
    • External markings: Tandem sub powder coated red to denote Shoot Positive

Borehole conditions (single fire)

  • Borehole fluids: No Restrictions
  • Tool positioning: Centralized | Eccentralized

Measurements (all single fire configurations except where noted)

  • Gamma Ray

    • Sensor type: Nal(Ti) Scintillation Gamma
    • Principle: Naturally Occurring Gamma
    • Sensor spacing: Proprietary
    • Sensitivity: Approximately 1.6 counts/API unit
    • Range: 0 to 5,000 cps
    • Vertical resolution: 14.00 in. (355.6 mm)
    • Precision: 5% at 100 GAPI at 15 fpm (4.6 m/min)
    • Data transmission: Analog, Pulse, + Polarity
    • Logging speed: Maximum: About 30 to 45 ft/min (9 to14 m/min)
    • Sample rate (3-1/8 in. single fire only): 4 to 10 samples/ft (10 to 40 samples/meter)
  • Casing Collar Locator

    • Sensor type: Dual Magnet, Center Coil
    • Principle: Magnetic Flux Variation
    • Sensor spacing: Proprietary
    • Sensitivity: Approximately 1.6 counts/API unit
    • Range: 0 to 5,000 cps
    • Vertical resolution: 14.00 in. (355.6 mm)
    • Precision: 5% at 100 GAPI at 15 fpm (4.6 m/min)
    • Data transmission: Analog, Line Wobble, mV

Calibrations (single fire)

  • 1-11/16 in. Single Fire

    • Primary: Approx. 1.0 cps/GAPI unit
    • Secondary: Thorium sleeve, API calibrated
    • Wellsite verifier: Thorium sleeve, API calibrated
  • 2-3/4 in. Single Fire

    • Primary: Approx. 1.6 cps/GAPI unit
    • Secondary: Thorium sleeve, API calibrated
    • Wellsite verifier: Thorium sleeve, API calibrated
  • 3-1/8 in. Single Fire

    • Primary: Approx. 1.0 cps/GAPI unit
    • Secondary: Thorium sleeve, API calibrated
    • Wellsite verifier: Thorium sleeve, API calibrated
  • 2-3/4 in. Single Fire Positive

    • Primary: Approx. 1.6 cps/GAPI unit
    • Secondary: Thorium sleeve, API calibrated
    • Wellsite verifier: Thorium sleeve, API calibrated