Weatherford International

Gamma Gun – Geiger Muller Tool

The Weatherford Gamma Gun – Geiger Muller tool is a rugged, compact gamma ray and casing collar locator device featuring a highly robust Geiger Muller detector and passive CCL, designed for cased-hole and perforating formation correlation applications, capable of operating reliably in extreme environments with maximum temperatures up to 350°F and pressures up to 20,000 psi, available in multiple sizes and configurations to accommodate various casing/tubing diameters and logging speeds up to 45 ft/min.

Gamma Gun – Geiger Muller Tool

Delivers accurate correlation of ballistic services

Applications

  • Cased-hole
  • Perforating formation correlation

Features and Benefits

  • Highly robust Geiger Muller detector
  • Compact gamma ray and casing collar locator (CCL)

Tool Description

The Weatherford gamma gun – Geiger Muller tool is a ruggedized tool fitted with a Geiger Muller detector on the lower section of the tool and a passive CCL at the top. The tool is designed to be run with a shooting adapter at the bottom to suit the customer’s choice of gun system. The rugged design enables the tool to operate reliably in the most extreme environments.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C) for 4 hours
  • Maximum pressure:
    • 1-11/16 in. Single Fire: 20,000 psi (138 MPa)
    • 1-11/16 in. Dual Fire: 20,000 psi (138 MPa)
    • 2-3/4 in. Single Fire Positive: 18,000 psi (124 MPa)
    • 2-3/4 in. Single Fire Negative: 18,000 psi (124 MPa)
    • 2-3/4 in. Dual Fire: 18,000 psi (124 MPa)
    • 3-1/8 in. Dual Fire: 18,000 psi (124 MPa)
  • Outer diameter:
    • 1.69 in. (42.9 mm)
    • 2.75 in. (69.85 mm)
    • 3.125 in. (79.375 mm)
  • Length:
    • 60.3 in. (1531.62 mm)
    • 73.2 in. (1859.28 mm)
    • 55.68 in. (1414.272 mm)
  • Weight:
    • 21.0 lb (9.5 kg)
    • 50.0 lb (23.0 kg)
    • 66.0 lb (29.94 kg)
  • Minimum casing/tubing OD:
    • 2.38 in. (60.5 mm)
    • 4.5 in. (114.3 mm)
  • Maximum casing/tubing OD:
    • 7.0 in. (178.0 mm)
    • 11.75 in. (298.45 mm)
  • Sensor depth offset:
    • Gamma Ray: 12.5 in. (317.5 mm), 20.8 in. (528.32 mm), 21.0 in. (533.4 mm)
    • CCL: 53.9 in. (1369.06 mm), 62.7 in. (1592.58 mm), 63.0 in. (1600.2 mm)

Borehole Conditions

  • Borehole fluids: No restrictions
  • Tool positioning: Centralized or Eccentralized
  • Logging speed: Maximum about 30 to 45 ft/min (9 to 14 m/min)

Measurements (all configurations except where noted)

  • Gamma Ray
    • Sensor type: Geiger-Muller detector
    • Detection type: Gamma Radiation
    • Principle: Naturally Occurring Gamma
    • Range: 0 to 5,000 cps
    • Data transmission: Analog, Pulse, + Polarity
    • Calibration (1-11/16 in. single and dual fire): Approx. 1.0 cps /GAPI unit
    • Calibration (all other configurations): Approx. 1.6 cps /GAPI unit
  • Casing Collar Locator
    • Sensor type: Dual Magnet, Center Coil
    • Detection type: Magnetic
    • Principle: Magnetic Flux Variation
    • Range: 0 to 5,000 cps
    • Data transmission: Analog, Line Wobble, mV

Electrical Specifications

  • 1-11/16 in. single and dual fire:
    • Cablehead voltage: 60 V Positive DC
    • Instrument current: 60 mA
    • Shooting polarity: Negative
  • All other configurations:
    • Operating voltage: 60V DC internally regulated
    • Operating current: 60 mA
    • Shooting power: 300V DC maximum, using only rollup method

Calibrations

  • Wellsite verifier: Thorium sleeve (for 2-3/4 in. and 3-1/8 in. configurations), API calibrated (for 3-1/8 in. Dual Fire)
  • Primary calibration: Approx. 1.6 cps/GAPI unit (for 2-3/4 in. Dual Fire)
  • Secondary calibration: Thorium sleeve, API calibrated (for 2-3/4 in. Dual Fire)

For more detailed technical information, refer to the Gamma Gun – Geiger Muller Tool Technical Specification Sheet (PDF).