Weatherford International

Flowmeter and Temperature Electronics Tool | Weatherford International

The Weatherford Flowmeter and Temperature Electronics Tool (FLTE) is a compact, robust device designed for wellbore fluid identification and temperature measurement, featuring a hall-effect flowmeter outputting 10 pulses per revolution with ±2 ft/min accuracy and a fast-response PRT temperature sensor accurate to 0.5°C, capable of operating up to 350°F and 15,000 psi, and compatible with high-speed digital telemetry tools for applications including production logging, leak detection, and flow profiling.

Flowmeter and Temperature Electronics Tool

Measures wellbore qualitative fluid identification data

Applications

  • Production logging flow and injection profiling
  • Conventional temperature logging
  • Leak detection, gas inflow points, top of cement
  • Basic “fracture height” determination
  • Flow behind pipe

Features and Benefits

  • Combinable with high-speed digital (HD) telemetry tools
  • Common base tool with multiple spinner options
  • Compact, versatile, and robust tool

Tool Description

The Weatherford flowmeter and temperature electronics tool (FLTE) is used with both the full-bore spinner and the fixed-cage spinner mechanical impeller.

A dedicated hall-effect array provides ten pulses per revolution flowmeter output and a fast-response PRT measures wellbore temperature.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C)
  • Maximum pressure: 15,000 psi (103.4 MPa)
  • Outside diameter: 1.69 in. (43.3 mm)
  • Length: 14.6 in. (371 mm)
  • Weight: 7.2 lb (3.3 kg)
  • Materials: Corrosion-resistant materials used throughout

Flowmeter Measurements

  • Output: 10 pulses per revolution
  • Maximum rps: 200 rps
  • Resolution: 2 ft (0.61 m)/min in water
  • Accuracy: ±2 ft (0.61 m)/min in water
  • Velocity max: 4,000 ft (1,219.2 m)/min with 4.0-in. (10.16-cm) pitch spinner

Temperature Measurements

  • Range: -40 to 350°F (-40 to 177°C)
  • Resolution: 0.006°F (0.003°C)
  • Accuracy: 0.9°F (0.5°C)
  • Linearity: 0.5°F (0.15°C)
  • Response time: Approx. 0.5 seconds

Hardware Characteristics

  • Combinability: All HD tools (RADii®, iQ™, PL, RAS™)
  • Acquisition mode: Real time with telemetry control unit (TCU); Memory with memory logging tool (MLT)

Electrical

  • Current: 7 mA at 50 V; 16 mA at 19 V

Technical Specification Sheet (PDF)