Fixed-Cage Spinner Mechanical Impeller
The Weatherford Fixed-Cage Spinner Mechanical Impeller is a corrosion-resistant, selectable fluid velocity tool compatible with 1 11/16-in. flow and temperature electronics (FLTE and CFT), designed for production logging and injection profiling with sizes ranging from 1.69 to 3.15 inches in diameter, capable of operating up to 350°F and 15,000 psi, providing centerline flow measurement with an output of 10 pulses per revolution and a velocity range exceeding 1,500 ft/min, and is combinable with high-speed digital telemetry tools for real-time or memory data acquisition.
Fixed-Cage Spinner Mechanical Impeller
Provides selectable fluid velocity.
Applications
- Production logging flow and injection profiling
Features and Benefits
- Combinable with flow and temperature electronics tool
- Centerline flow measurement at bottom of toolstring
- Variable size options for compatibility with minimum wellbore restriction
Tool Description
The Weatherford fixed-cage spinner mechanical impeller is run in combination with either the 1 11/16-in. flow and temperature electronics tool (FLTE), which combines the flowmeter sensor electronics with a fast-response temperature tool, or with the 1 11/16-in. combined capacitance, flow and temperature tool (CFT).
Selected size depends on the minimum restriction in the completion. The protected impeller assembly minimizes the possibility of damage in hole.
Specifications
Ratings and Dimensions
- Maximum temperature: 350°F (177°C)
- Maximum pressure: 15,000 psi (103.4 MPa)
- Outside diameter:
- FCSM01: 1.69 in. (43.3 mm)
- FCSM02: 2.13 in. (54 mm)
- FCSM04: 3.15 in. (80 mm)
- Length:
- FCSM01: 6.5 in. (0.65 m)
- FCSM02: 6.9 in. (175 m)
- FCSM04: 7.5 in. (191 m)
- Weight:
- FCSM01: 1.4 lb (0.65 kg)
- FCSM02: 1.6 lb (0.72 kg)
- FCSM04: 2.2 lb (1 kg)
- Materials: Corrosion-resistant materials used throughout
Measurement
- Output: 10 pulses per revolution
- Threshold: <5 ft/min (1.5 m/min)
- Range: Better than 1,500 ft/min
- Maximum rps (measured by FLTE or CFT): 200 rps
Hardware Characteristics
- Combinability: All high-speed digital (HD) telemetry production logging tools, including RADii®, iQ™, RAS™ when connected to FLTE and CFT
- Acquisition mode: Real time (with telemetry control unit); Memory (with memory logging tool)