Weatherford International

Compensated Neutron Tool

The Weatherford Compensated Neutron Tool is a slim-profile, through-casing neutron porosity and gas identification instrument that operates only when run with a 2.75-in. digital gamma ray tool, featuring a 15 curie Am241 Be neutron source, dual He3 gas detectors spaced at 16.32 and 21.36 inches, capable of measuring porosity from -3 to 60 units with ±2% accuracy under borehole conditions including salt, fresh, and oil fluids, rated for up to 350°F and 20,000 psi, and combinable with Radii® cement bond and other logging tools.

Compensated Neutron Tool

Provides gas identification and measures porosity through the casing.

Applications

  • Through-casing porosity
  • Gas identification

Features and Benefits

  • Combinable with Radii® cement bond tools
  • Configurable-source installation
  • Slim profile

Tool Description

The Weatherford compensated neutron tool must be run in conjunction with a 2.75-in. digital gamma ray tool. It cannot be run alone.

Specifications

Ratings and Dimensions

  • Maximum temperature: 350°F (177°C) (for 4 hours)
  • Maximum pressure: 20,000 psi (138 MPa)
  • Outside diameter: 2.75 in. (69.85 mm)
  • Length: 61.68 in. (1,566.67 mm)
  • Weight: 60 lb (27.2kg)
  • Min casing/tubing OD: 4.5 in. (115 mm)
  • Max casing/tubing OD: 9.63 in. (244.6 mm)
  • Tensile strength:
    • Tension: 15,000 lb
    • Compression: 35,000 lb
    • Torque: 150 ft.lbf
  • Measure points:
    • Near detector (SS): 16.32 in. (414.53 mm)
    • Far detector (LS): 21.36 in. (542.54 mm)

Strengths apply to new tools at 70°F (21°C) and 0 psi.

Borehole Conditions

  • Borehole fluids: Salt, fresh, and oil
  • Logging speed:
    • Recommended: 35 ft/min (10 m/min)
    • Max: 60 ft/min (18.2 m/min)
  • Tool positioning: Centralized, eccentralized

Hardware Characteristics

  • Source type: 15 curie Am241 Be neutron emitter
  • Sensor type: One He3 Gas Detector Tube each
  • Sensor spacing:
    • Near Detector (SS): 17.5 in. (444.5 cm)
    • Far Detector (LS): 27.5 in. (698.5 cm)
  • Transmission rate: 20 frames/s
  • Waveform: Digital telemetry data
  • Combinability: GR, CCL (required), RADii®, CBT, digital CBT

Measurements

  • Type: Neutron porosity
  • Principle: Ratiometric thermal neutron detection
  • Range: -3 to 60 porosity units
  • Vertical resolution: Approximately 10 in. (254 mm)
  • Depth of investigation: Porosity dependent, 12 in. or less (304.8 mm or less)
  • Accuracy (1SD): ± 2%
  • Primary curves:
    • Neutron API units
    • Near and far detector count rates
  • Secondary curves: Detector count-rate ratio

Calibration

  • Primary: University of Houston API neutron pit
  • Secondary: Neutron calibration tank
  • Wellsite verifier: 350-micron curie active verifier