Compensated Neutron Tool
The Weatherford Compensated Neutron Tool is a slim-profile, through-casing neutron porosity and gas identification instrument that operates only when run with a 2.75-in. digital gamma ray tool, featuring a 15 curie Am241 Be neutron source, dual He3 gas detectors spaced at 16.32 and 21.36 inches, capable of measuring porosity from -3 to 60 units with ±2% accuracy under borehole conditions including salt, fresh, and oil fluids, rated for up to 350°F and 20,000 psi, and combinable with Radii® cement bond and other logging tools.
Compensated Neutron Tool
Provides gas identification and measures porosity through the casing.
Applications
- Through-casing porosity
- Gas identification
Features and Benefits
- Combinable with Radii® cement bond tools
- Configurable-source installation
- Slim profile
Tool Description
The Weatherford compensated neutron tool must be run in conjunction with a 2.75-in. digital gamma ray tool. It cannot be run alone.
Specifications
Ratings and Dimensions
- Maximum temperature: 350°F (177°C) (for 4 hours)
- Maximum pressure: 20,000 psi (138 MPa)
- Outside diameter: 2.75 in. (69.85 mm)
- Length: 61.68 in. (1,566.67 mm)
- Weight: 60 lb (27.2kg)
- Min casing/tubing OD: 4.5 in. (115 mm)
- Max casing/tubing OD: 9.63 in. (244.6 mm)
- Tensile strength:
- Tension: 15,000 lb
- Compression: 35,000 lb
- Torque: 150 ft.lbf
- Measure points:
- Near detector (SS): 16.32 in. (414.53 mm)
- Far detector (LS): 21.36 in. (542.54 mm)
Strengths apply to new tools at 70°F (21°C) and 0 psi.
Borehole Conditions
- Borehole fluids: Salt, fresh, and oil
- Logging speed:
- Recommended: 35 ft/min (10 m/min)
- Max: 60 ft/min (18.2 m/min)
- Tool positioning: Centralized, eccentralized
Hardware Characteristics
- Source type: 15 curie Am241 Be neutron emitter
- Sensor type: One He3 Gas Detector Tube each
- Sensor spacing:
- Near Detector (SS): 17.5 in. (444.5 cm)
- Far Detector (LS): 27.5 in. (698.5 cm)
- Transmission rate: 20 frames/s
- Waveform: Digital telemetry data
- Combinability: GR, CCL (required), RADii®, CBT, digital CBT
Measurements
- Type: Neutron porosity
- Principle: Ratiometric thermal neutron detection
- Range: -3 to 60 porosity units
- Vertical resolution: Approximately 10 in. (254 mm)
- Depth of investigation: Porosity dependent, 12 in. or less (304.8 mm or less)
- Accuracy (1SD): ± 2%
- Primary curves:
- Neutron API units
- Near and far detector count rates
- Secondary curves: Detector count-rate ratio
Calibration
- Primary: University of Houston API neutron pit
- Secondary: Neutron calibration tank
- Wellsite verifier: 350-micron curie active verifier