Array Fluid Velocity Resistance Capacitance Tool
The Weatherford Array Fluid Velocity Resistance Capacitance Tool is a compact, six-arm multi-sensor production logging device designed for whole wellbore fluid characterization, deviated wellbore production profiling, and complex flow evaluation by measuring fluid velocity, resistivity, and capacitance with co-located sensors arranged radially, capable of bi-directional flow analysis, operating up to 350°F and 15,000 psi, and combinable with other HD services and Array Gas Holdup tools for comprehensive three-phase flow evaluation.
Array Fluid Velocity Resistance Capacitance Tool
Measures array fluid velocity, resistivity, and capacitance
Applications
- Whole wellbore fluid characterization
- Deviated wellbore production profiling
- Complex flow evaluation
Features and Benefits
- Co-located fluid velocity and holdup measurements
- Six-sensor packages arranged radially on 6 arms
- Bi-directional fluid flow evaluation
- Combinable with all HD services
- Can operate in SRO or Memory
- Combinable with Array Gas Holdup for 3-phase flow evaluation
Tool Description
The Weatherford array fluid velocity resistance capacitance tool is a compact 6-arm multi-sensor array production logging tool. Each arm provides three measurements via a fluid velocity sensor, and a co-located fluid resistance and fluid capacitance sensor.
The sensor configuration offers optimal coverage of the wellbore cross section. The tool is run with centralizers and the opening diameter of the arms should be adjusted to avoid contamination from debris on the casing wall, and to minimize risk of damage in open hole or horizontal sections.
Specifications
Rating and Dimensions
- Maximum temperature: 350°F (177°C)
- Maximum pressure: 15,000 psi (103.4 MPa)
- Outer diameter: 1.69 in. (43.0 mm)
- Length: 80.0 in. (2,003.00 mm)
- Weight: 35.0 lb (15.9 kg)
- Measure points:
- Fluid Velocity (Short, x3): 25.4 in. (645.0 mm)
- Fluid Velocity (Long, x3): 29.5 in. (749.0 mm)
- Resistance and Capacitance (Short, x3): 23.0 in. (584.0 mm)
- Resistance and Capacitance (Long, x3): 27.0 in. (686.0 mm)
Measurements
- Adjustment range: Up to 9.0 in (228.6 mm)
- Velocity output: +/- 300 rps, <10-500 FPM
- Velocity threshold: <10 FPM water
- Resistance output: Frequency; Post Log Processing determines Water Hold Up % (A Quicklook Real-time Hold-up is presented during logging)
- Capacitance output: Frequency; Post Log Processing determines Water Hold Up %
Hardware Characteristics
- Acquisition mode: Real-time (with TCU), Memory (with MLT)
- Combinability: All HD tools (RADii, iQ, PL, RAS, etc.) when connected to TCU
- Materials: Corrosion resistant materials used throughout
- Tool positioning: Centralized
- Deviation: 0 - 180° and Tool rotation 0 – 360°
Electrical Specifications
- Current: 40 mA at 50 V; 105 mA at 19 V